Sign In | Join Free | My burrillandco.com
Home > Low Voltage Switchgear >

Outdoor Construction Site Circuit Control Box Power Distribution Board Single Door

Guangzhou Hengmeida Automation Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Outdoor Construction Site Circuit Control Box Power Distribution Board Single Door from wholesalers
     
    Buy cheap Outdoor Construction Site Circuit Control Box Power Distribution Board Single Door from wholesalers
    • Buy cheap Outdoor Construction Site Circuit Control Box Power Distribution Board Single Door from wholesalers

    Outdoor Construction Site Circuit Control Box Power Distribution Board Single Door

    Ask Lasest Price
    Model Number : kH415415677
    Certification : ISO9001,CCC
    Payment Terms : T/T,Western Union
    Delivery Time : 15 Days
    Price : USD28-68889
    • Product Details
    • Company Profile

    Outdoor Construction Site Circuit Control Box Power Distribution Board Single Door

    Outdoor Construction Site Circuit Control Box Power Distribution Cabinet



    Product Describe:

    Outdoor Construction Site Circuit Control Box Power Distribution Cabinets are widely used in various outdoor construction scenarios. In highway and railway construction, they power large machinery and manage temporary facility power, adapting to complex terrains with dustproof and waterproof designs. At building construction sites, they distribute electricity for construction machinery and temporary areas, facilitating flexible wiring. In oil and gas field operations, they provide power with explosion-proof features and resist corrosion. For mining and quarry sites, they power heavy machinery, distribute electricity for underground systems, and support high-current output. In infrastructure projects like bridges and tunnels, they supply power for equipment, manage temporary systems, and have high protection ratings. In renewable energy construction, they power installation equipment, manage temporary power, and integrate with energy storage systems.


    Design:

    ParameterSpecification
    Rated Dispersal Factor0.8
    Insulation Material Name and Heat Resistance RatingDMC, Heat Resistance Class F
    Rated Frequency50Hz
    Rated Voltage380V
    Rated Insulation Voltage660V
    Rated Impulse Withstand Voltage6kV
    Rated Current of Main Busbar40A - 630A
    Rated Short - time Withstand Current of Main Busbar15kA
    Rated Peak Withstand Current of Main Busbar30kA
    Rated Current of Main Switch40A - 630A
    Rated Short - circuit Breaking Capacity of Main Switch (Icu)Type; 18kA
    Rated Operational Short - circuit Breaking Capacity of Main Switch (Ics)Type; 14kA
    Number of Outgoing Circuits4 circuits, 5 circuits, 6 circuits
    Rated Current of Outgoing Circuits (Inc)4 Circuits: 1, 2, 3, 4 branches, 100A; 5 Circuits 1, 2, 3, 4, 5 branches, 100A; 6 Circuits 1, 2, 3, 4, 5, 6 branches, 100A
    Rated Short - circuit Withstand Current of Outgoing Circuits (Icc)5kA


    Material:

    Cold rolled steel /Stainless Steel


    IP Rating:IP55/IP65/IP66


    OEM / ODM Suggestion :

    1. Clarify core requirements first
    Power load: Determine the number of circuits and circuit breaker specifications based on the total power of equipment (e.g., a 250kW load requires a large-sized cabinet) to avoid underloading or redundant waste.
    2. Installation scenario: For outdoor/humid environments, prioritize IP55 protection and stainless steel (SUS304); for dry indoor scenarios, galvanized steel plates can be chosen to reduce costs.
    Installation method: Wall-mounted models should be compact with a height ≤500mm; floor-standing models need to consider maintenance space, with a recommended depth ≥300mm.
    3. Size customization: Precisely adapt to space
    If installation space is limited (e.g., narrow equipment rooms), adjust according to the principle of "prioritizing width reduction while ensuring depth/height meets component layout" (e.g., 300×200×400mm for low-load equipment).
    If integrating multiple modules (e.g., surge protection + multi-circuit sockets), a depth ≥250mm is recommended to reserve space for wiring and heat dissipation.
    4. Functional customization: Focus on core scenarios
    Industrial construction sites: Prioritize customizing explosion-proof switches and 63A industrial sockets to adapt to heavy-duty equipment.
    Temporary power distribution: Choose modular terminal blocks for easy quick disassembly; redundant protection modules can be omitted to reduce costs.
    Lightning-prone areas: Mandatorily add surge protection modules (e.g., Class T2) to enhance safety.